Learning Phase Carryover - Tests the learning phase carryover feature across a month boundary.
Analysis: What Does This Simulation Prove?
What this proves: At the start of each month, the system enters a "learning phase" until
enough peaks are recorded. By default, it uses the minimum limit during learning, which can allow unnecessarily high
peaks. With "carryover mode" enabled, the system instead uses a percentage (e.g., 80%) of the previous month's peak
average. This 40-day simulation crosses from January into February, demonstrating how the system maintains reasonable
limits at the month boundary instead of starting fresh. Watch the limit changes around February 1st - with carryover,
the system doesn't drop to the minimum limit but continues with an appropriate target based on January's performance.
Without Battery
3.5 kW
Unmanaged peak average
With Battery
2 kW
Battery-assisted peak average
Reduction
-43%
1.5 kW saved
Monthly Cost Impact: Based on typical Swedish effekttariff rates (~50 SEK/kW/month),
this 1.5 kW reduction saves approximately
75 SEK/month on the power tariff portion of your grid fee.
Battery Contribution: The battery discharged during 120 peak hours
with an average discharge rate of 1.3 kW to shave consumption peaks.
| Metric |
Without Battery |
With Battery |
Savings |
| Peak Average |
3.5 kW |
2 kW |
-43% |
| Highest Peak |
3.50 kW |
2.00 kW |
-43% |
| Est. Monthly Cost* |
175 SEK |
100 SEK |
-75 SEK |
*Estimated using typical Swedish effekttariff rate of ~50 SEK/kW/month. Actual rates vary by provider.